Universal controller VRD3


00131918_0

UNIVERSAL, DYNAMIC

For different actuators

Modular control components for VAV terminal units

  • Module selection based on application
  • Actuators with selected actuator forces

Options

  • Actuators with safety function for 'damper blade OPEN' and 'damper blade CLOSED' (spring return actuators)

Application

Application

  • Electronic volume flow controllers of Type Universal (dynamic) are designed for use with VAV terminal units.
  • Dynamic differential pressure transducer and electronic controller are fitted together in one casing
  • Actuator or spring return actuator is separate
  • The output signals of the room temperature controller, central BMS, air quality controller or similar units control the volume flow rate setpoint
  • Override control by means of switches or relays
  • Volume flow rate actual value is available as linear voltage signal
  • Controller parameters are factory set
  • On-site adjusting is not required

Standard filtration in comfort air conditioning systems allows for use of the controller in the supply air without additional dust protection. Since a partial volume flow is passed through the transducer in order to measure the volume flow rate, please note:

  • With heavy dust levels in the room, suitable extract air filters must be provided.
  • If the air is polluted with fluff or sticky particles or contains aggressive media, Universal (dynamic) controllers cannot be used

Description

Parts and characteristics

  • Sensor for dynamic differential pressure measurements
  • Separate actuator
  • Mechanical stops for limiting the damper blade positions
  • Actuators with overload protection
  • Release button to allow for manual operation

Technical information

Function, Produktbeziehungen

  • Function
Principle of operation – Universal 00134465_0
① Differential pressure transducer
② Actuator
③ Volume flow controller
④ Setpoint value signal


Functional description

VAV terminal units control the volume flow in a closed loop, i.e. measurement – comparison – control.

The volume flow rate is determined by measuring the differential pressure (effective pressure). For this purpose the VAV terminal unit is fitted with a differential pressure sensor.

The integral differental pressure transducer transforms the effective pressure into a voltage signal. The volume flow rate actual value is hence available as a voltage signal. The factory setting is such that 10 V DC always corresponds to the nominal volume flow rate (Vnom).

The volume flow rate setpoint value comes from a higher-level controller (e.g. room temperature controller, air quality controller, central BMS) or from switch contacts. Variable volume flow control results in a value between Vmin and Vmax. It is possible to override the room temperature control, e.g. by a complete shut-off of the duct.

The controller compares the volume flow rate setpoint value to the actual value and controls the integral actuator accordingly.

The volume flow rate parameters Vmin and Vmax are factory set on potentiometers. Voltage ranges are factory stored in the controller. Changes on the customer's site can easily be carried out using an adjustment device or a notebook with service tool.

Volume flow control

  • The volume flow controller works independent of the duct pressure
  • Differential pressure fluctuations do not result in permanent volume flow rate changes
  • To prevent the control from becoming unstable, a dead band is allowed within which the damper blade does not move.
  • The factory set volume flow rate parameters can be altered by the customer

Variants, MP bus/Analogue, Analogue

  • VARIANTS
  • MP BUS/ANALOGUE
  • ANALOGUE

Any attachments are to be defined with the order code of the VAV terminal unit.

Universal controller, dynamic, for VAV terminal units

Order code detail Controller Actuator Type of VAV terminal unit
Part number Type Part number Type

B13

M546GA4

VRD3

M466DJ8

NM24A-V

① ② ④

B11

M546GA4

VRD3

M466DG8

SM24A-V

B1B

M546GA4

VRD3

M466DR1

NF24A-V (spring return actuator)

① ② ③ ④

B27

M546GA4

VRD3

M466DJ8

NM24A-V

XC3

M546ED4

GUAC-D3

A00000051738

361C-024-20-V/ST07 (spring return actuator)

① ② ③ ④

① TVR

② TVJ

③ TVT

④ TZ-Silenzio, TA-Silenzio, TVZ, TVA

⑤ TVM


Downloads

informazioni di prodotto

manuali d'uso

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Condividi pagina

Consiglia questa pagina

Consiglia questa pagina inviando un link via e-mail.

I campi contrassegnati con (*) sono obbligatori.

Condividi pagina

Grazie per la tua condivisione!

La tua segnalazione è stata inviata e dovrebbe arrivare a breve.


Contatti

Siamo qui per te

Specifichi il suo messaggio ed il tipo di richiesta
Tel.: +39 029829741 | Fax: +39 0298297460

I campi contrassegnati con (*) sono obbligatori.

Contatti

Grazie per il tuo messaggio!

Il tuo messaggio è stato inviato e sarà processato a breve.
Il nostro dipartimento per la gestione delle richieste ti contatterà appena possibile.
Per domande di carattere generale riguardanti i nostri prodotti o servizi, è possibile contattare:
Tel.: +39 029829741 | Fax: +39 029829760

Contatti

Siamo qui per te

Specifichi il suo messaggio ed il tipo di richiesta
Tel.: +39 029829741 | Fax: +39 0298297460

Attachment (max. 10MB)

I campi contrassegnati con (*) sono obbligatori.

Contatti

Grazie per il tuo messaggio!

Il tuo messaggio è stato inviato e sarà processato a breve.
Il nostro dipartimento per la gestione delle richieste ti contatterà appena possibile.
Per domande di carattere generale riguardanti i nostri prodotti o servizi, è possibile contattare:
Tel.: +39 029829741 | Fax: +39 029829760